Fluke 117 vs 87V: Which Multimeter Should You Buy?

JHOTAS electrical educator presenting illustrated Fluke 117 and 87V multimeters on a workshop bench.

Fluke 117 vs 87V is really a question of job type, not which meter is “better.” For residential and commercial building electrical work, the Fluke 117 is usually the more practical choice because it is compact, includes non-contact voltage detection, and has Auto-V/LoZ to help suppress ghost-voltage readings. For industrial maintenance, motor drives, plant automation, and higher-energy distribution work, the Fluke 87V justifies its higher cost with a VFD low-pass filter, temperature measurement, higher safety category ratings, and deeper troubleshooting functions.

Quick Verdict: Fluke 117 vs 87V

  • Buy the Fluke 117 if most of your work is outlets, lighting, panels, branch circuits, commercial buildings, schools, hospitals, or general electrical service.
  • Buy the Fluke 87V if you regularly troubleshoot VFDs, motors, industrial controls, plant equipment, higher-voltage distribution, or need temperature and higher-resolution diagnostic functions.

If your daily work is mostly normal building wiring, paying extra for the 87V may not improve the jobs you perform most often. If you troubleshoot industrial motor drives, however, the 117 can leave you without features the 87V was specifically designed to provide.

Already know which features you need? Compare current Fluke 117 and 87V listings, then check the included accessories and condition before choosing.

Fluke 117 vs 87V Specifications

FeatureFluke 117Fluke 87V
Primary useCommercial / building electrical workIndustrial troubleshooting
True RMSYesYes
Non-contact voltage detectionVoltAlert built inNot a headline 87V function
Ghost-voltage suppressionAuto-V/LoZIndustrial diagnostic features are the focus
VFD low-pass filterNo dedicated VFD filterYes
TemperatureNo built-in temperature functionYes, with temperature probe support
Safety ratingCAT III 600VCAT III 1000V / CAT IV 600V
DC voltage rangeUp to 600VUp to 1000V
Best fitElectricians and building serviceIndustrial electricians and maintenance
As an eBay Partner, I may be compensated if you make a purchase.

Can the 117 Replace an 87V for Low-Current Measurements?

Check the smallest current you need to measure before buying. The 117 specifies 0.001 A resolution on its 6 A range: that is 1 mA, or 1,000 microamps per display step. It does not provide a dedicated microamp range. The 87V provides microamp measurement, so the difference matters for small control currents as well as motor-drive work.

Display counts are a separate issue: the 117 has 6,000 counts; the 87V has 6,000 normally and 19,999 in its high-resolution mode. More counts do not make every measurement more accurate. Check the function-specific accuracy and range in the manual.

Safety: a non-contact indication or a LoZ reading alone does not prove equipment is safe to touch. Measurement category, leads, test procedure and training must suit the circuit. Do not connect a current input across a supply.

Why the Fluke 117 Makes Sense for Building Electricians

The 117 is built around the kinds of problems electricians see in occupied buildings. Its integrated VoltAlert function gives a quick non-contact indication of energized conductors, while Auto-V/LoZ helps reduce false readings caused by capacitive coupling and ghost voltage.

That LoZ function can be especially useful when troubleshooting a conductor that shows a suspicious voltage with a standard high-impedance meter. Instead of immediately treating every measured voltage as a solid energized source, the electrician can use the lower-impedance mode to help distinguish a weak induced voltage from a source capable of supplying meaningful current.

The 117 also measures AC/DC voltage, current, resistance, continuity, frequency, and capacitance, and it includes Min/Max/Average recording. For outlet problems, lighting circuits, breaker identification, and general commercial electrical troubleshooting, that covers a large share of everyday work.

→ Related Guide: Outlet Not Working but Breaker Isn’t Tripped? Here’s What to Check

→ Related Guide: How to Find Which Breaker Controls an Outlet Safely

For a different electrical problem that calls for correctly rated test equipment and careful diagnosis, see Why a Breaker Trips When the Air Conditioner Starts. Do not probe live equipment without suitable training.

Why the Fluke 87V Is Better for Industrial Troubleshooting

The 87V is designed for a different environment. Fluke positions it for motor drives, plant automation, power distribution, and electromechanical equipment. Its low-pass filter is a major reason industrial technicians choose it because variable frequency drives produce pulse-width-modulated waveforms and high-frequency noise that can confuse a general-purpose meter.

The 87V also adds a built-in temperature measurement function, higher DC-voltage range, higher safety category ratings, high-resolution display mode, and fast peak capture for short transients. Those features are useful when the job involves motors, drives, control cabinets, and industrial distribution rather than just branch-circuit troubleshooting.

Is the Fluke 87V Worth the Extra Cost?

It is worth the extra cost when you will actually use the industrial features. Paying more for CAT III 1000V / CAT IV 600V capability, VFD measurements, temperature, and transient capture makes sense if those are part of your work.

If you mainly check receptacles, lighting circuits, service calls, commercial building panels, and normal AC loads below 600V, the 117 may be the better tool because you are paying for features that match your daily tasks instead of features that may sit unused.

For someone building a tool kit from scratch, I would rather buy the meter that matches the work and spend the remaining budget on good leads, an appropriate clamp meter, proving equipment, and other test tools than automatically choose the most expensive multimeter.

Which One Should Electricians Buy?

UserBetter fitWhy
Residential electricianFluke 117Compact, LoZ, VoltAlert, standard building measurements
Commercial building electricianFluke 117Strong match for everyday service and troubleshooting
Industrial electricianFluke 87VVFD filter, higher ratings, advanced diagnostics
Motor / drive technicianFluke 87VDesigned for noisy PWM drive signals
Facility maintenance technicianDepends on equipment117 for building systems; 87V for industrial plant equipment

Where to Check Current Prices

Prices change frequently, especially when comparing a meter-only listing with kits that include leads, cases, clamps, or temperature accessories. Check exactly what is included before comparing two listings.

Compare both models before buying: check the complete meter price, included leads, seller condition, calibration evidence and return terms. When a current price is unavailable here, the button opens matching eBay search results. Prices and availability can change without notice.

BUYING CHECKLIST

Fluke 117 Electrician Multimeter

Check Fluke 117 on eBay →

As an eBay Partner, I may be compensated if you make a purchase.

BUYING CHECKLIST

Fluke 87V Industrial True-RMS Multimeter

Check Fluke 87V on eBay →

As an eBay Partner, I may be compensated if you make a purchase.

For another tool comparison focused on everyday building work, see Fluke 117 vs Klein MM700: features, safety categories and discontinued-model considerations.

Buying a Used Fluke 117 or 87V: What to Check

  • Inspect the input jacks for heat or arc damage.
  • Check that the correct high-energy fuse is installed in the current input.
  • Inspect test leads for damaged insulation and exposed metal.
  • Confirm the display, selector switch, continuity beeper, and input functions work normally.
  • Ask about calibration history if measurement accuracy matters for your work.
  • Be cautious with unusually cheap listings where authenticity or condition is unclear.

FAQ

Is the Fluke 87V safer than the 117?

The 87V has higher published category ratings: CAT III 1000V and CAT IV 600V, compared with CAT III 600V for the 117. But a higher category rating does not replace safe work practices, proper PPE, correctly rated leads, or verifying the circuit before measurement.

Are both meters True RMS?

Yes. Both are True-RMS meters, which is useful for non-linear AC loads. The 87V adds specialized filtering for noisy VFD signals.

What is the biggest advantage of the Fluke 117?

For building electricians, the combination of Auto-V/LoZ, VoltAlert, compact size, and core True-RMS measurement functions is the main advantage.

What is the biggest advantage of the Fluke 87V?

The 87V is much better suited to industrial troubleshooting, especially variable frequency drives, motors, plant automation, and higher-energy electrical systems.

Bottom Line

Choose the Fluke 117 for residential and commercial building electrical work. Choose the Fluke 87V when industrial equipment, VFDs, motors, temperature, and higher-category distribution measurements are part of your normal job.

The 87V is the more capable industrial instrument, but that does not automatically make it the better purchase for every electrician. The better meter is the one whose specialized functions match the systems you actually troubleshoot.

For available electrician meters and other contractor equipment, browse JHOTAS Jobsite Tool Deals & Price Watch. Check the model, condition, CAT rating and included test leads before buying.

About the author

I have practical experience in electrical construction and electrical project coordination in South Korea. For U.S.-focused guides, I research official codes, government data, utility documents, and manufacturer specifications to explain electrical and energy topics as accurately and practically as possible.

Sources & Official References

As an eBay Partner, I may be compensated if you make a purchase.

Is there something you’d like to see?

Suggest an electrical topic, practical guide, or calculator you would like to see on JHOTAS-LAB. Your suggestion may help shape future content.